Menu
Advertising
- Delta Q Quiq Charger Manual
- Deltaq Quiq Charger Manual
- Delta Q Quiq Charger Fault Codes
- Delta-q Quiq Battery Charger Manual
- Delta Q Quiq Charger Algorithms
Delta-Q Technologies QuiQ HF Battery Chargers manuals and user guides for free. Read online or download in PDF without registration. View and Download Delta-Q QuiQ user manual online. HF/PFC Battery Charger. QuiQ Battery Charger pdf manual download. QuiQ 1000 Battery Charger Flexibility included. The versatile design of QuiQ 1000 provides manufacturers with flexibility and battery charging performance. The QuiQ 1000 is usable on or off-board, and contains up to 10 optimized charge profiles for lead acid and lithium-ion batteries. Electric vehicle battery charger, High reliability high performance unbeatable value. Read online or download PDF. Delta-Q Technologies QuiQ PFC Battery Chargers User Manual. Delta-Q Technologies QuiQ PFC Battery Chargers User Manual. Operating instructions. Delta-Q Technologies Power suppliers. Manuals Directory ManualsDir.com - online owner manuals library. Delta-Q Technologies manuals. Power suppliers.
Note: This is a Class A product complying with United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 15. In a domestic
environment this product may cause radio interference, in which case the user may be required to take adequate measures.
environment this product may cause radio interference, in which case the user may be required to take adequate measures.
2009 © Delta-Q Technologies Corp. All rights reserved. PN: 710-0098 Rev 1
4. Optional Charger Single-LED Display (internal or external)
LED Colour
Indication (following “Power-On Self Test”)
Green
Solid:
Charging complete. Network monitor software mac os x. Charger in Maintenance Mode.
Flashing:
Short: <80% Charge.
Long: >80% Charge.
When battery is not connected: Algorithm Number
display.
display.
Amber
Flashing:
Reduced Power Mode: Low AC Voltage or High
internal charger temperature.
internal charger temperature.
Red
Flashing:
Charger error. Reset charger power and refer to
Troubleshooting Instructions below.
Troubleshooting Instructions below.
Maintenance Instructions
-
1. Do not expose charger to oil, dirt, mud or direct heavy water spray when cleaning vehicle.
2. If the detachable input power supply cord set is damaged, replace with a cord that is:
a.) for North America - UL or CSA listed/approved detachable cord, 3 conductor, 16AWG minimum, and rated SJT;
terminating in a grounding type IEC 60320 C14 plug rated 250V, 13A minimum; or
b.) for all other countries – a safety approved detachable cord, 3 conductor, 1.5mm² minimum, rated appropriately for
industrial use. The cord set must be terminated on one end with a grounding type input connector appropriate for
use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug.
use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug.
3. The enclosure of the charger has been tested successfully to EN60529, meeting IP66. The AC supply inlet is rated to Free kubota manual download.
IP20, which is suitable for indoor use only. Keep all AC connections clean and dry.
Troubleshooting Instructions
-
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Cause
Solution
Battery High Voltage
Check battery size and condition and reset charger
(interrupt AC power for 15 seconds).
(interrupt AC power for 15 seconds).
Battery Low Voltage
Check battery size and condition and reset charger
(interrupt AC power for 15 seconds).
(interrupt AC power for 15 seconds).
Charge Timeout caused by
battery pack not reaching required
voltage. Charger output was
reduced due to high temperatures
battery pack not reaching required
voltage. Charger output was
reduced due to high temperatures
Check connections.
Operate charger at a lower ambient temperature.
Check Battery: battery could not
be trickle charged up to minimum
voltage
be trickle charged up to minimum
voltage
Check for shorted or damaged cells.
Over-Temperature: Charger shut
down due to high internal
temperature.
down due to high internal
temperature.
Ensure sufficient cooling air flow and reset charger
(interrupt AC power for 15 seconds).
(interrupt AC power for 15 seconds).
Charger Internal Fault
Reset charger (interrupt AC power for 15 seconds).
Return to qualified service depot if fault persists.
Return to qualified service depot if fault persists.
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising
Delta-Q Technologies Corp.
3755 Willingdon Ave
Burnaby, BC V5G 3H3
Canada
tel: 604.327.8244
fax: 604.327.8246
email: [email protected]
www.delta-q.com
For more information contact:
Electric Vehicle
Battery Charger
• Advanced high frequency design with > 90% efficiency and >.99 power factor
• Wide range AC input (85 - 265 VAC) for worldwide operation
• Fully sealed enclosure provides improved reliability in demanding environments
• Approved battery charge algorithms for ideal charging
• Integrated Charge Tracking for Advanced Troubleshooting and Charge History Analysis
• Wide range AC input (85 - 265 VAC) for worldwide operation
• Fully sealed enclosure provides improved reliability in demanding environments
• Approved battery charge algorithms for ideal charging
• Integrated Charge Tracking for Advanced Troubleshooting and Charge History Analysis
subject to change without notice
720-0001 R
ev 5 October 7, 2011
QuiQ HF/PFC Battery Charger Specifications
QuiQ and the Power in Motion slogan are
trademarks of Delta-Q Technologies Corp.
Copyright © 2006 Delta-Q Technologies Corp.
QuiQ Model: 912- or 913-
24xx 36xx 48xx 72xx 84xx 96xx
DC Output
DC Output Voltage - nominal
24 V 36 V 48 V 72 V 84 V 96 V
DC Output Voltage - maximum
34 V 51 V 68 V 100 V 120 V 135 V
DC Output Current - maximum
25 A
21 A
18 A
12 A
10 A
9 A
DC Output Power - maximum
695 W 875 W 1000 W 1000 W 1000 W 1000 W
Interlock Current - maximum
1 A
1 A
1 A 0.5 A 0.5 A 0.5 A
Battery Type
Specific to selected algorithm
Reverse Polarity
Electronic protection – auto-reset
Short Circuit
Electronic current limit
AC Input
AC Input Voltage - range
85 - 265 VAC
AC Input Voltage - nominal
120 VAC / 230 VAC rms
AC Input Frequency
45 - 65 Hz
Delta Q Quiq Charger Manual
AC Input Current - maximum/nominal 12 A / 9.5 A rms @ 120 VAC or 5 A rms @ 230 VAC
AC Power Factor - nominal
AC Power Factor - nominal
> 0.99 @ 120 VAC / > 0.98 @ 230 VAC
Mechanical
Dimensions
28.0 x 24.6 x 11.0 cm (11 x 9.7 x 4.3”) Download manual 1943 farmall h.
Weight
< 5 kg (< 11 lbs) w/standard output cord
AC input connector
IEC320/C14 (require ≥ 1.8m localized cord)
DC output connector
OEM specific w/12AWG wire
Environmental
Enclosure
IP66 (NEMA4)
Operating Temperature
-30°C to +50°C (-22°F to 122°F), derated
above 30°C (86°F), below 0°C (32°F)
Storage Temperature
-40°C to +70°C (-40°F to 158°F)
Regulatory
Instant pot duo plus series user manual. Safety
UL approved to UL1564 3rd Ed., and CSA 107.2,
EN 60335-2-29, Designed to meet UL2202 1st Ed.
Emissions
2005 glastron gx 205 user manual. FCC Part 15/ICES 003 Class A, EN 55011,
EN 61000-3-2, EN 61000-3-3
Deltaq Quiq Charger Manual
Immunity
EN 61000-4-2/-3/-4/-5/-6/-11
Operation
AC ON
Delta Q Quiq Charger Fault Codes
Solid YELLOW AC LED
>80% Charge Indicator
Solid YELLOW Charge LED
100% Charge Indicator
Solid GREEN Finish LED
Fault Indicator
Flash RED Fault LED
DC Ammeter
LED Bargraph (6 level)
Long-term Storage Mode
Auto-restart if battery voltage < 2.1 V/cell or 30 days elapse Yamaha ypt-300 manual download.
Special Features
Battery Temperature Monitoring with Multiple Temperature Sensor Options
External Communications
External Communications
PC-based configuration software for field programmability
Advanced Microprocessor with Integrated Charge Cycle and Event Tracking
Advanced Microprocessor with Integrated Charge Cycle and Event Tracking
Options
• OEM Specific DC Output Cord
• Localized AC Input Cord
• Reverse or Dry Contact Interlocks
• Handle
• Localized AC Input Cord
• Reverse or Dry Contact Interlocks
• Handle
Delta-q Quiq Battery Charger Manual
Rear view of QuiQ ICON configuration shows inline DC and signal
connectors (charger output on left, signal I/O on right).
Mate with OEM specific output cords.
HF/PFC Battery Chargers
246
mm
9.7'
260 mm
10.2'
125
Delta Q Quiq Charger Algorithms
mm
4.9'
278 mm
10.9'
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals